S7-LAN - smales gateway for Industrial Ethernet - TCP/IP - for every kind of Simatic-S7
|
Demo/Documentation |
order data / price list |
operation / use

The S7-LAN module is connected directly to the MPI or Profibus interface of the SIMATIC S7. The device has the shape and size of a Profibus connector. In addition, the module has a quasi "piggyback" Profibus connection. In this way S7-LAN can be easily integrated into existing MPI / Profibus network. In the module of the ethernet RJ45 connector is integrated. Thus S7-LAN is a very compact and small device. Two LEDs are displaying the functional state of the module.
configuration
Each S7-LAN module gets its own IP address. This address enables the connected S7-MPI/Profibus networkk be achieved. The IP address can be fixed, or obtained from a DHCP server. The operation of the router (gateway) is possible. The configuration is done in a simple way via the S7-LAN manager for Windows and the integrated web server. This software is included.
operation with the STEP 7 software

For programming with STEP 7 in specially developed driver included. S7-Lan, we thus directly addressed by the step S7 software. Those who wish can also a virtual comport. Both drivers are included
visualization / SCADA runs parallel

S7-LAN can be operated in the so-called CP mode (communication processor mode). Then, the device behaves like a CP343-1. Immediately visualizations such as WinCC (SCADA) or common OPC server data exchange with S7.
watching of PLC's variables over integrated WEB interface

watch variables of the PLC without operation panel
use the integrated WEB interface
| specification |
|
| supply voltage | 24 V/DC +/- 20% |
| power consumption | 2 watt |
| display | WEB interface two status LED's |
| configuration / handling | WEB interface manager software (included) |
| interfaces | to the PLC: PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd to the PD/PC: PD/diagnosis jack 10/100BaseTX RJ45-ethernet jack |
| galvanic separation | 1500V PPI/MPI/Profibus to the PC |
| operating temperature | 5 - 55°C |
| case | ABS-plastic case |
| dimensions | 65 x 43 x 17 mm |
| operating system | MS-Windows NT,2000, XP, Vista, 7 or other like linux with S7-TCP/IP driver IP-S7-LINK |
| order number | designation |
|
9352-LANCon |
S7-LAN Modul |
| 9352-LAN | MPI-LAN Cable |